LogoLogo
WebsiteResource HubDownloadBook a DemoContact Support
Theia Apollo - v2024
Theia Apollo - v2024
  • Theia3D Documentation
    • Theia3D Documentation
    • Welcome to Theia3D
    • Keyboard Shortcuts
    • Getting Started
      • System Requirements
      • Installation
      • License Activation
      • Startup Window
      • Theia3D Basics
    • Data Collection
      • Data Collection Principles
      • Recording Intrinsic Lens Calibrations
      • Recording Extrinsic Chessboard Calibrations
      • Recording Extrinsic Object Calibrations
    • Theia3D Interface
    • Theia3D Dropdown Menus
      • File Menu
      • Analyze Menu
      • Display Menu
      • Results Menu
      • Calibration Menu
        • Check Calibration
        • Lens Calibration
        • Chessboard Calibration
        • Object Calibration
        • Adjust Calibration
      • Tools Menu
        • Check Synchronization
        • Organize Videos
        • Format Sony Multicam
        • Assign Calibration Files
        • Modify People IDs
        • Toggle Views
        • Display Video Metadata
        • Enhance Videos
      • Settings Menu
        • Settings Menu
        • Analysis Preferences
        • Rendering Preferences
        • Setup Preferences
      • Help Menu
    • Theia Model Description
      • Default Model Description
      • Full Body Model Description
      • Separate Arm and Head Model Description
    • Data Formats
      • Video Data
      • Calibration Files
      • Theia3D Workspaces
      • C3D Files
      • FBX Files
      • JSON Files
    • Batch Processing
      • Theia3D Batch Application
      • File Menu
      • Help Menu
      • Settings
      • Trials
      • Preferences
    • Camera System Requirements
    • Sony Camera Package
      • Components
      • System Setup
      • Collecting Data with the System
  • Troubleshooting
    • Troubleshooting Documentation
    • Error Messages
      • Input directory has no mp4 or avi files.
      • Videos not formatted properly
      • Only [#] videos found.
      • Videos not the same length.
      • Unsupported video codec detected
      • Unable to load calibration.
      • Required camera parameter groups not present
      • Qualisys calibration has inconsistent FOV
      • Data not loaded
      • Camera extrinsics optimization step 3 failed
      • Unable to construct a continuous volume from overlapping chessboard frames
      • Track people not complete
      • Abnormally high tracking errors
      • Invalid video
    • Visible Issues
      • Coordinate system is out of place in one camera view
      • Coordinate system is in different positions and/or orientations in all camera viewse
      • Coordinate system is in an incorrect but consistent position and/or orientation in all views
      • Skeleton is consistently outside the body
      • Skeleton is momentarily incorrect
      • Skeleton is incomplete
      • Skeleton is completely missing
      • Skeleton is jittery
    • Sony Troubleshooting
      • Initialization issues
      • Unstable Connection
    • Other Issues
Powered by GitBook

Links

  • About
  • Terms of Use
  • Privacy Policy

Resources

  • Download
  • FAQ
  • Blog
On this page
  • Explanation
  • Possible Solutions

Was this helpful?

Export as PDF
  1. Troubleshooting
  2. Error Messages

Camera extrinsics optimization step 3 failed

PreviousData not loadedNextUnable to construct a continuous volume from overlapping chessboard frames

Last updated 2 months ago

Was this helpful?

Explanation

This error message arises when the chessboard calibration algorithm is unable to calculate the position and orientation of the cameras relative to the chessboard. More than one chessboard may have been detected in the calibration trial videos, which can be caused by extra chessboards present in the capture volume or mirrors positioned around the capture volume.

Possible Solutions

  1. Reduce the Frame Grab Step. If the chessboard was detected in too few frames to be calibrated due to a high Frame Grab Step value being used, it may be possible to calibrate the system with a lower Frame Grab Step value. Lower the Frame Grab Step value and run the calibration again.

  2. Collect a new calibration trial. If the camera system has not be taken down or modified since the data were collected and the data were collected relatively recently (within 48 hours), a new calibration trial can be recorded. Address the source of the problem (e.g. remove extra chessboards or cover mirrors) and collect a new calibration trial.