LogoLogo
WebsiteResource HubDownloadBook a DemoContact Support
Theia Axiom - v2025
Theia Axiom - v2025
  • Theia3D Documentation
    • What's New
    • Theia3D Documentation
    • Welcome to Theia3D
    • Keyboard Shortcuts
    • Getting Started
      • System Requirements
      • Installation
      • License Activation
      • Startup Window
      • Theia3D Basics
      • Camera Setup Tips
      • Tutorial Videos
    • Data Collection
      • Data Collection Principles
      • Recording Intrinsic Lens Calibrations
      • Recording Extrinsic Chessboard Calibrations
      • Recording Extrinsic Object Calibrations
    • Theia3D Interface
    • Theia3D Dropdown Menus
      • File Menu
      • Analyze Menu
      • Display Menu
      • Results Menu
      • Calibration Menu
        • Check Calibration
        • Lens Calibration
        • Chessboard Calibration
        • Object Calibration
        • Adjust Calibration
      • Tools Menu
        • Check Synchronization
        • Organize Videos
        • Format Sony Multicam
        • Assign Calibration Files
        • Modify People IDs
        • Toggle Views
        • Display Video Metadata
        • Enhance Videos
      • Settings Menu
        • Settings Menu
        • Analysis Preferences
        • Rendering Preferences
        • Setup Preferences
      • Help Menu
    • Theia Model Description
      • Default Model Description
      • Full Body Model Description
      • Separate Arm and Head Model Description
    • Data Formats
      • Video Data
      • Calibration Files
      • Theia3D Workspaces
      • C3D Files
      • FBX Files
      • JSON Files
      • Video Overlays
    • Theia3D Batch
      • Theia3D Batch Interface
      • Setting Up a Batch
      • File Menu
      • Help Menu
      • Settings
      • Trials
      • Preferences
      • Batch Processing Outputs
    • Camera System Requirements
    • Sony Camera Package
      • Components
      • System Setup
      • Data Collection
  • Troubleshooting
    • Troubleshooting Documentation
    • Error Messages
      • License Errors
        • License Activation Failed
      • Organize Data Errors
        • Input directory has no mp4 or avi files
      • Load Video Data Errors
        • Videos not formatted properly
        • Only [#] videos found
        • Videos are not the same length
        • Unsupported video codec detected
        • Invalid video
      • Load Calibration File Errors
        • Unable to load calibration
        • Required camera parameter groups not present
      • Load Workspace Errors
        • Selected folder does not contain a valid Theia workspace
        • Incompatible workspace
      • Calibration Errors
        • Camera extrinsics optimization step 3 failed
        • Unable to detect chessboard in overlapping frames for all cameras
        • Too few chessboards detected (<25)
        • Field of view coverage insufficient (<60%)
      • Movement Trial Processing Errors
        • Track people not complete
        • Abnormally high tracking errors
    • Visible Issues
      • Coordinate system is out of place in one camera view
      • Coordinate system is in different positions and/or orientations in all camera viewse
      • Coordinate system is in an incorrect but consistent position and/or orientation in all views
      • Skeleton is consistently outside the body
      • Skeleton is momentarily incorrect
      • Skeleton is incomplete
      • Skeleton is completely missing
      • Skeleton is jittery
    • Sony Troubleshooting
      • Initialization Issues
      • Unstable Connection
    • Other Issues
Powered by GitBook

Links

  • About
  • Terms of Use
  • Privacy Policy

Resources

  • Download
  • FAQ
  • Blog
On this page
  • Recommendations:
  • Avoid:
  • Recording Chessboard Calibrations:

Was this helpful?

Export as PDF
  1. Theia3D Documentation
  2. Data Collection

Recording Extrinsic Chessboard Calibrations

PreviousRecording Intrinsic Lens CalibrationsNextRecording Extrinsic Object Calibrations

Last updated 3 days ago

Was this helpful?

Extrinsic chessboard calibration trials are used to determine the position and orientation of every camera in your camera system relative to your desired global coordinate system. As with lens calibration trials, users with wand calibration-capable systems (e.g. Qualisys Miqus, Vicon FLIR Blackfly S systems) are not required to complete chessboard calibration.

A minimum of one chessboard calibration trial should be collected every time you set up your camera system, but collecting multiple is recommended. A new calibration is required any time a camera is moved, so having multiple calibration trials collected throughout a long data collection session can help prevent data loss due to accidental or unnoticed camera movements.

Chessboard calibrations must be performed at the resolution that will be used to record your movement data. If you will be using more than one resolution during your data collection, you must record chessboard calibration trials at each resolution.

Recommendations:

  • Record chessboard calibration trials at a relatively low frame rate (20-30 Hz) to reduce file size and processing time.

  • Keep the chessboard as flat as possible during the calibration trial.

  • Focus on achieving groupings of 3+ cameras that can see the chessboard at all times.

  • Align the chessboard with marks on the ground so you can confirm that the global coordinate system is positioned correctly when processing movement trials.

Avoid:

  • Obstructions and occlusions; be aware of any objects within your capture volume which may partially or completely block the chessboard pattern from the view of the cameras. Even partial obstructions of the chessboard pattern may prevent it from being detected.

    • For treadmill capture volumes, be aware of treadmill safety rails, harnesses, etc.

    • For athletic environments, be aware of safety netting or equipment. Where possible, move or remove netting during calibration to ensure a direct view of the calibration chessboard.

  • High frames or excessively long calibrations; chessboard calibration recordings produce the strongest result when many diverse perspectives of the chessboard are captured. Longer calibrations can provide more diverse data, but it is best to avoid high frame rates or excessively long calibrations to avoid long processing times.

Recording Chessboard Calibrations:

  1. Set up your camera system as desired for your data collection, following the recommendations in .

  2. Choose or place visible marks on the ground which will be aligned with the global coordinate system, for confirmation when processing data.

  3. Check that the chessboard is fully visible in at least 3 camera views when it is placed at the desired global coordinate system origin position.

  4. Begin the recording.

  5. Slowly ‘show’ the chessboard to groupings of 3 or more cameras while varying the position and orientation of the chessboard slightly. Ensure the chessboard is visible to cameras that overlap between groupings, ideally so that no fewer than 3 cameras can see the chessboard at all times. Focus on achieving groupings of 3+ cameras at all times.

  6. When you are confident that all cameras have had sufficient views of the chessboard, slowly place the chessboard on the ground, aligned with your preselected marks.

  7. Ensure you are not obstructing the view of the chessboard in any cameras during this localization phase.

  8. End the recording.

To process extrinsic chessboard calibrations, see .