LogoLogo
WebsiteResource HubDownloadBook a DemoContact Support
Theia Apollo - v2024
Theia Apollo - v2024
  • Theia3D Documentation
    • Theia3D Documentation
    • Welcome to Theia3D
    • Keyboard Shortcuts
    • Getting Started
      • System Requirements
      • Installation
      • License Activation
      • Startup Window
      • Theia3D Basics
    • Data Collection
      • Data Collection Principles
      • Recording Intrinsic Lens Calibrations
      • Recording Extrinsic Chessboard Calibrations
      • Recording Extrinsic Object Calibrations
    • Theia3D Interface
    • Theia3D Dropdown Menus
      • File Menu
      • Analyze Menu
      • Display Menu
      • Results Menu
      • Calibration Menu
        • Check Calibration
        • Lens Calibration
        • Chessboard Calibration
        • Object Calibration
        • Adjust Calibration
      • Tools Menu
        • Check Synchronization
        • Organize Videos
        • Format Sony Multicam
        • Assign Calibration Files
        • Modify People IDs
        • Toggle Views
        • Display Video Metadata
        • Enhance Videos
      • Settings Menu
        • Settings Menu
        • Analysis Preferences
        • Rendering Preferences
        • Setup Preferences
      • Help Menu
    • Theia Model Description
      • Default Model Description
      • Full Body Model Description
      • Separate Arm and Head Model Description
    • Data Formats
      • Video Data
      • Calibration Files
      • Theia3D Workspaces
      • C3D Files
      • FBX Files
      • JSON Files
    • Batch Processing
      • Theia3D Batch Application
      • File Menu
      • Help Menu
      • Settings
      • Trials
      • Preferences
    • Camera System Requirements
    • Sony Camera Package
      • Components
      • System Setup
      • Collecting Data with the System
  • Troubleshooting
    • Troubleshooting Documentation
    • Error Messages
      • Input directory has no mp4 or avi files.
      • Videos not formatted properly
      • Only [#] videos found.
      • Videos not the same length.
      • Unsupported video codec detected
      • Unable to load calibration.
      • Required camera parameter groups not present
      • Qualisys calibration has inconsistent FOV
      • Data not loaded
      • Camera extrinsics optimization step 3 failed
      • Unable to construct a continuous volume from overlapping chessboard frames
      • Track people not complete
      • Abnormally high tracking errors
      • Invalid video
    • Visible Issues
      • Coordinate system is out of place in one camera view
      • Coordinate system is in different positions and/or orientations in all camera viewse
      • Coordinate system is in an incorrect but consistent position and/or orientation in all views
      • Skeleton is consistently outside the body
      • Skeleton is momentarily incorrect
      • Skeleton is incomplete
      • Skeleton is completely missing
      • Skeleton is jittery
    • Sony Troubleshooting
      • Initialization issues
      • Unstable Connection
    • Other Issues
Powered by GitBook

Links

  • About
  • Terms of Use
  • Privacy Policy

Resources

  • Download
  • FAQ
  • Blog
On this page
  • Explanation
  • Possible Solutions

Was this helpful?

Export as PDF
  1. Troubleshooting
  2. Error Messages

Unable to construct a continuous volume from overlapping chessboard frames

PreviousCamera extrinsics optimization step 3 failedNextTrack people not complete

Last updated 2 months ago

Was this helpful?

Explanation

This error message arises when the chessboard calibration trial does not contain sufficient frames of overlapping visibility of the chessboard in 3 or cameras throughout the trial. This prevents the camera system from being properly calibrated, as there is insufficient information to calculate the position and orientation of all cameras in the system in 3D space.

Possible Solutions

  1. Reduce the Frame Grab Step If the chessboard was detected in too few overlapping frames between camera groupings to form a continuous volume, it may be possible to calibrate the system with a lower Frame Grab Step value. Lower the Frame Grab Step value and run the calibration again.

  2. Collect a new calibration trial. If it is not possible to reduce the Frame Grab Step to increase the overlapping visibility of the chessboard, it will be required to record a new calibration trial. If the camera system has not been taken down or modified since the data were collected and the data were collected relatively recently, a new calibration trial can be recorded. When recording the new calibration trial(s), be sure to focus on achieving an overlap in visibility of the chessboard surface in 3 or more cameras throughout the trial, and ensure that all camera groupings are linked by this overlap.